This website uses cookies to store information on your computer. Some of these cookies are used for visitor analysis, others are essential to making our site function properly and improve the user experience. By using this site, you consent to the placement of these cookies. Click Accept to consent and dismiss this message or Deny to leave this website. Read our Privacy Statement for more.
NFRC News Now
Blog Home All Blogs

2020 Fall Membership Meeting Committee Recap

Posted By Adriana Vargas, National Fenestration Rating Council, Wednesday, October 28, 2020

Research and Technology Committee Report

  • * The Board approved the Non-Planar Skylight Energy Ratings RFP. This RFP will assist with developing procedures to rate non-planar products using computer simulation.

  •  

Technical Committee Report

  • * Volunteers are needed, please contact the staff liaison.

  • Vice-chair for the Condensation Resistance SC (Chair: Steve Harp; Staff liaison: Dennis Anderson)


  • * The following ballots were approved, but are held in abeyance until the next authorized ANSI review and approval and will be implemented upon publication:

  • ANSI/NFRC 100 Spandrel ballot to determine U-factor ratings for spandrel products.

  • ANSI/NFRC 200 Spandrel ballot to determine SHGC and VT ratings for spandrel products.

  • These two spandrel ballots require the updating and approval of the NFRC simulation manual to include modeling procedures for spandrel products. 

  • ANSI/NFRC 500 Refinement ballot which clarifies language for the new Condensation Index (CI) procedure. 

  • This ballot clarifies the following: the center-of-glass CI determination is the coldest temperature between dividers or glass when applicable; that blinds or shades-between-the-glass can be simulated for CI for inside the glazing gap only; and aligns the CI physical test procedure for placement of divider-edge thermocouples to match the simulation procedure and figures.


  • * Due to the complications to use updates of WINDOW and THERM software (version 7.7 or greater), the Board approved moving the sunset date for WINDOW/THERM version 7.4 to June 30, 2021.

  • The WINDOW/THERM Approval task group is developing an RFP to test version 7.8 of the WINDOW and THERM software.


  • * Information:

  • Kevin Vilhauer of Katerra, has taken on the role of Vice Chair of the Technical Committee. 

  • The Condensation Index software tool will go through the Software Approval process. This software will assist simulators with obtaining temperatures from THERM for use with the CI rating.


Ratings Committee Report

  • * The Board approved the reaffirmation of the NFRC 700 and NFRC 705 program documents as 2021 documents with implementation upon publication.

  •  

  • By the end of the year, NFRC program documents, such as the NFRC 701, 702, etc., shall be approved as 2021 documents. All 2021 program documents shall be published in January of 2021.


ANS Standards Committee Report

  • * The Board approved the ANS Committees recommendation to move ANSI/NFRC documents to a Continuous Maintenance review cycle

  • Staff has been directed to update documents and submit documentation to ANSI/ANAB for processing. NFRC anticipates moving to the continuous maintenance process by mid-2021.

Tags:  ANSI  committee  conference  energy efficiency  fenestration  meetings  report 

PermalinkComments (0)
 

NFRC Ballots for the Mid-Cycle meeting, July 13, 2020

Posted By Adriana Vargas, National Fenestration Rating Council, Monday, June 22, 2020

Ratings Committee

 1.       NFRC 700 Glazing Description

The purpose of this ballot is to change the required information for the temporary label on certified products.

  • The change makes all the glazing description optional instead of mandatory.
  • The number of glass panes has also been added to the text describing the glazing description.
  • The tint colors also have been incorporated into the single glazing description paragraph.
  • Manufacturers that currently print a glazing description on their label may continue to do so.
  • There are no required or mandatory changes that a manufacturer must make to their labels as a result of this ballot.

2.       NFRC 700 Condensation Index

The purpose of this ballot is to remove the NFRC 500 Condensation Rating and replace it with the ANSI/NFRC 500 Condensation Index.

  • Implementation will not take place until the LEAFF pilot program is completed in late 2020.
  • PCP participants that want to utilize the NFRC 500 Condensation Resistance Rating in certification authorizations can do so until the implementation of the ANSI/NFRC 500 Condensation Index and implementation or publication in the NFRC 700 PCP.
  • Implementation of the Condensation Index will require modification to the Certified Products Directory.

Technical Committee

 1.       ANSI/NFRC 100 Reporting Ratings

The purpose of this ballot is that ANSI/NFRC 100 is corrected to strike any reference to report metric U-factor to the nearest .05 W/m2K and strictly use proper rounding of the result to two decimal points.

  • Per NFRC 700, there is no language that states metric rating of U-factor shall be rounded to the nearest 0.05 W/m2K but, consistently throughout the document it states that the U-factor rating shall be displayed on the NFRC label as rounded to two decimals.
  • The sample labels confirm that the metric U-factor is not required to be rounded to the nearest 0.05 W/m2K as shown in Figures A-5 and A-9.
    • The U-factor in those sample labels show a metric U-factor of 1.99 W/m2K and is confirmed to match the I-P (Imperial) value of 0.35 Btu/hr/ft2/F.
    • The conversion is calculated, as required by NFRC 700, as 5.678263.
    • This conversion is the value used by the laboratories when converting metric to I-P in their reports as well as the CPD 2.0 Upload Spreadsheet.
  • 2.       ANSI/NFRC 100 Spandrel

    The purpose of this ballot is to add language to include the simulation of all spandrel panel systems to the NFRC program.

    • The Spandrel Validation Task Group has met a few times to address all questions and negative comments from the NFRC Fall Membership Meeting in Charlotte in 2019.
    • Previously, spandrel glass only was able to be simulated, which has always been a limitation to the NFRC program for commercial manufacturers of glazed wall systems. 
    • Research was conducted and presented at the NFRC Fall Membership meeting in Albuquerque in 2018 that proved that spandrel systems with interior opaque metal insulation panels can be simulated and backed up by validation testing.
    • The conclusions of the research indicated that more than 63.5mm of glass edge is required and that 254mm of glazing edge shall be required for an accurate simulation.
    • The simulation methodology shall be presented to TIPC for their review and approval and inserted into the Simulation Manual upon approval of ANSI/NFRC 100.

    3.       ANSI/NFRC 200 Equation 4-3

    This correction to NFRC 200 will make any work done for the LEAFF program consistent with the calculations WINDOW has always used.

    • During the work to move forward with the LEAFF program, it was discovered that the exterior heat transfer coefficient in Equation 4-3 was in error. 
    • The value of 30 W/m2K in the equation is for the winter conditions and the SHGC is calculated under summer conditions.
    • The WINDOWS program from LBNL has always used the summer exterior heat transfer coefficient of 20.6 W/m2K.

    4.       ANSI/NFRC 200 Spandrel

    This is the second ballot to add language to include the simulation of all spandrel panel systems to the NFRC program. 

    • Previously, spandrel glass only was able to be simulated and that has always been a limitation to the NFRC program for commercial manufacturers of glazed wall systems. 
    • Research was conducted and presented at the NFRC Fall Membership meeting in Albuquerque in 2018 that proved that spandrel systems with interior opaque metal insulation panels can be simulated and backed up by validation testing.
    • The research findings indicated that more than 63.5mm of glass edge is required and that 254mm of glazing edge shall be required for an accurate simulation.
    • The simulation methodology shall be presented to TIPC for their review and approval and then inserted into the Simulation Manual upon approval of ANSI/NFRC 100.

    5.       ANSI/NFRC 500

    This ballot is to make further refinements to the new Condensation Index procedure and to also address some comments that came from NFRC's ANS Committee.

    6.       NFRC 501

    This ballot is to change the reference to the distance the glass edge temperature is to be taken. 

    • All documents and the software tool referencing the Condensation Index shall have consistent language that the glass edge temperature shall be obtained at 25mm and not 25.4mm.  
    • Only section 1.2 of NFRC 501 is shown with Underline/Strikeout for balloting.


    Research and Technology Committee

     1.       NFRC 101 Appendices

    This ballot is intended to update the source references for the material properties listed in Appendices A and B and to update the properties based on those new references.

    • This is a follow up to the ballot from the Virtual Spring Committee 2020 meeting.
    • The changes marked in this ballot are the last remaining changes that had negative comments associated with them from the previous ballots.
    • All other changes have been approved from the previous ballots.

    Staff does not anticipate any additional document changes, no legal review, or additional cost for implementation. The default THERM materials library will be revised to incorporate the changed Appendices after final approval of the document.

    • The implementation plan suggested by the task group is for the new appendices to be used no earlier than Jan. 1, 2021.
    • Once implemented, the new data shall be used for all new certifications, revisions, and addenda to existing product lines.
    • All existing product lines and products in the CPD at the time of implementation will be able to remain until the end of the certification cycle for that product line.

    2.       NFRC 101 Non-homogenous Spacer

    This ballot revises Section 5.1.7.2 relating to conductivity measurements of non-homogeneous spacer samples. Four changes are proposed:

    • An upper limit on the thickness of the foam rubber sheets.
    • Test method revisions based on the laboratory equipment capability
    • Specifying the removal of the contribution of the glass to the thermal resistance of the specimen
    • Clarifying the reference to EN675.

    To register to the Mid-Cycle Virtual Meeting, click here.

    Tags:  ANSI  Ballots  fenestration  NFRC ratings  NFRC700  ratings  virtual meeting 

    PermalinkComments (0)
     
    About Us

    The National Fenestration Rating Council (NFRC) is the trusted, independent, nonprofit certification body for the energy performance of windows, doors, and skylights. With more than 35 years of expertise, NFRC is the standard-bearer in fenestration performance certification, providing the public with objective data that helps stakeholders make informed decisions about product and building performance. NFRC certification ensures that products are tested using precise, scientifically validated methods, resulting in ratings that are fair, accurate and credible. Contact us at info@nfrc.org.